// MS UET

Optimus Red Sound Level Meter

Specifications

Applicable Standards

IEC 61672-1:2002 Class 1 or Class 2 Group X

IEC 60651:2001 Type 1 I or Type 2 I

IEC 60804:2000 Type 1 or Type 2

IEC 61252:1993 Personal Sound Exposure Meters

ANSI S1.4 -1983 (R2006), ANSI S1.43 - 1997 (R2007)

ANSI S1.25:1991

1:1 Octave Band Filters to IEC 61260 & ANSI S1.11-2004 (C & D variants)

Microphone

Class 1 MK:224 pre-polarized, Class 2 MK:216 pre-polarized

Microphone Preamplifier

MV:200 Removable Preamplifier (All versions)

Total Measurement Range:

20dB to 140dB RMS Single Range

Noise Floor: <18dB(A) Class 1, <21dB(A) Class 2

Frequency Weightings

RMS & Peak : A, C, & Z Measured Simultaneously

Frequency Bands: 10 Octave Bands (31.5Hz to 16kHz, C & D variants)

Time Weightings

Fast, Slow & Impulse Measured Simultaneously

Display

High resolution OLED display. Ambient light sensor & illuminated keypad

Memory

4GB (B, C & D Versions), 32GB factory fit option

AuditStore

Measurement verification data stored in secure memory

Time History Data Rates (Global settings)

10ms, 62.5ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (User selectable)

VoiceTag Audio Recording (B, C & D Versions)

Up to 30 seconds of audio notes with each measurement

Integrators

Three simultaneous "virtual" noise meters. Integrator 1 is preset to Q3 for Leq functions. Integrators 2 & 3 can be configured with the following:

Exchange Rate: 3, 4 or 5 dB

Threshold: 70dB to 120dB (1 dB steps)

Time Weighting: None or Slow

Criterion Level: 70dB to 120dB (1 dB steps)

Criterion Time: 1 to 12 hours in 1 hour steps

Integrator Quick settings

EU, OSHA HC & OSHA NC, OSHA HC & ACGIH,

MSHA HC & MSHA EC, Custom 1 & Custom 2

Measurement control

Pause & Back Erase with user selectable duration

Dimensions

Size: 283mm x 65mm x 30mm

Weight: 300gms/10oz

Batteries

4 x AA Alkaline

Battery life

Typically 12 hours with Alkaline AA

Typically 20 hours with Lithium AA Non-Rechargeable

Battery life is dependent upon the battery type, quality & screen brightness

Connections

USB Type B to PC

AC & DC Output via ZL:174 (2 x Phono, 1m)

Multi-pin IO for external power via ZL:171 cable (2.1mm socket)

External Power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket)

Tripod Mount

1/4" Whitworth socket

Case

Material: High Impact ABS-PC with soft touch back & keypad

Environmental

Temperature: Operating -10°C to +50°C, Storage -20°C to +60°C

Humidity: Up to 95% RH Non Condensing

Electromagnetic performance

IEC 61672-1:2002 & IEC 61672-2:2003

Except where modified by EN 61000-6-1:2007 & EN 61000-6-1:2007

Language options

English, French, German, Spanish. Other language options may be available

Software Support

NoiseTools Download, Configuration & Analysis software supplied as standard. Compatible with Microsoft Windows XP, Vista, 7 & 8 (32bit & 64bit)

Measurement Functions

CR:162A & CR:161A

Displayed Functions

LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE

Graph of Short LAeq, LCPeak

Integrators 2 & 3: TWA, Dose%, Est Dose%v

Measurement Run Time

CR:162B & CR:161B

Displayed Functions

LXY, LXYMax, LXYMin,,LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq

Graph of Short LAeq, LCPeak

Measurement Run Time

Integrators 2 & 3: TWA, Dose%, Est Dose%

Stored Functions

LXYMax & Time History of LXYMax

LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak

Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq

Integrators 2 & 3: LAVG , TWA. %Dose

Time History of LAVG

CR:162C & CR:161C

Displayed Functions

LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq

Graph of Short LAeq, LCPeak

Measurement Run Time

Integrators 2 & 3: TWA, Dose%, Est Dose%

Real-Time Octave Band Filters

Stored Functions

LXYMax & Time History of LXYMax

LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak

Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq

Integrators 2 & 3: LAVG , TWA. %Dose

Time History of LAVG

Octave Bands: Overall Leq & Leq Time History for each band

Measurement Run Time

Time & Date of Measurement Start

CR:162D & CR:161D

Displayed Functions

LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq

Graph of Short LAeq, LCPeak

Measurement Run Time

Integrators 2 & 3: TWA, Dose%, Est Dose%

Real-Time Octave Band Filters

NR & NC values & curves

Stored Functions

LXYMax & Time History of LXYMax

LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak

Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq

Integrators 2 & 3: LAVG , TWA. %Dose

Time History of LAVG

Octave Bands: Overall Leq & Leq Time History for each band

NR & NC values & curves

Measurement Run Time

Time & Date of Measurement Start

where x=A ,C ,Z; y= F, S, I

Other functions may calculated by the NoiseTools software and displayed on download.

The Perfect Solution of Occupational Noise Measurements

Optimus Red Sound Level Meters

Measuring noise at work doesn't need to be a time-consuming task. The Optimus Red Sound Level Meter uses the very latest digital technology to save you time.

By measuring every parameter you need simultaneously, it can record everything in one measurement. There's no concern about choosing the wrong function or missing any data. All you need to do to get going is switch on, calibrate and start. It's that simple.

All of your measurement data displays on the large OLED screen, so you can see straight away if there are any occupational noise problems in your workplace. You can easily navigate screens to see the data you need during measurements.

Whether you need to meet the UK and EU Regulations, measure to OSHA HC & PEL, MSHA, ACGIH

See what the Optimus Red can do for you. Use the form to contact our Noise Experts today.

Why Choose Optimus Red?

  • Backed by 15 Year no quibble warranty for your peace of mind
  • High Performance to Class 1 or Class 2 Standard
  • Quick, simple and easy to operate
  • Measures Fast, Slow & Impulse Time Weightings
  • dB(A), dB(C) and dB(Z) Frequency Weightings included
  • Real-time 1:1 Octave Band Filters (optional)
  • VoiceTagTM voice note recording
  • AuditStoreTM measurement verification
  • High resolution colour OLED display and back-lit keypad
  • Measure up to 140dB(A) and 143dB(C) Peak with a single 120dB measurement range
  • Long battery life

Product Details

  • Brand: Cirrus Research
  • Product Code: CK161 & CK162
  • Availability: Call for availability

Product Downloads

  • £POA


Available Options